Water is the most used ingredient in any dairy plant – it flows through every stage of production, from cleaning equipment to processing milk itself. Yet it’s also one of the most overlooked quality variables. Poor water quality doesn’t just affect the taste of your final product; it can corrode expensive processing equipment, interfere with microbial cultures, and create conditions for contamination. That’s why systematic water quality testing is not optional – it’s a core part of dairy quality assurance. Five key parameters form the foundation of this testing: hardness, pH, sulphite ions, phosphate ions, and residual chlorine.
Table of Contents
- Why water quality matters in dairy processing
- Testing water hardness by EDTA titration
- Measuring pH with pH paper
- How pH affects chlorine effectiveness
- Detecting sulphite ions by iodate-iodide titration
- Identifying phosphate ions by colorimetric methods
- Measuring residual chlorine: Tolidine and Chlorotex methods
- The Tolidine (OT) method
- The Chlorotex method
- Testing frequency and sampling strategy
- Connecting water quality to product quality
Why water quality matters in dairy processing
Dairy plants consume large volumes of water for product formulation, equipment cleaning, cooling, and sanitation. Any chemical imbalance in this water can cascade into product defects and compliance failures. To be suitable for use in dairies, water must be sanitary and free of microorganisms that could in any way start spoilage. Beyond microbial concerns, dissolved minerals and chemical residues in water can affect everything from the texture of dairy cultures to the lifespan of stainless steel pipelines.
The Food Safety and Standards Authority of India (FSSAI) publishes standardized methods for analyzing water used in the processed food industry, including dairy operations. These methods cover both physicochemical and microbiological parameters, ensuring a comprehensive approach to water safety.
Testing water hardness by EDTA titration
Water hardness refers to the concentration of dissolved calcium and magnesium salts. Hardness is defined as a characteristic of water representing the total concentration of calcium and magnesium ions expressed as calcium carbonate. In a dairy plant, hard water is a practical problem – it causes scale deposits inside boilers, heat exchangers, and pasteurizers, reducing thermal efficiency and increasing maintenance costs. Very soft water, on the other hand, can be corrosive to metal equipment.
The standard laboratory method for measuring hardness is complexometric titration using EDTA (Ethylenediaminetetraacetic acid). EDTA acts as a strong chelating agent that binds calcium and magnesium ions one-to-one. The procedure works as follows: a measured volume of water is placed in a conical flask, an ammonia buffer (pH 10) is added, and a few drops of Eriochrome Black T (EBT) indicator are introduced. The indicator forms a wine-red complex with calcium and magnesium ions. As EDTA solution is added from a burette, it competitively binds the calcium and magnesium ions; once all ions are bound, the free EBT reverts to its natural blue color, marking the end point.
The volume of EDTA consumed is used to calculate hardness, expressed in mg/L as CaCOโ. Hardness (EDTA) in mg/L = (A ร T ร 1,000) / S, where A is the mL of EDTA used, T is the titer of EDTA in mg CaCOโ per mL, and S is the sample volume in mL. Dairy plants generally aim for water hardness in the range of 50-150 ppm as calcium carbonate. Water below 50 ppm can be corrosive to pipes, while water above 150 ppm tends to form scaling deposits on heat transfer surfaces.
Measuring pH with pH paper
The pH of water reflects its acidity or alkalinity on a scale of 0 to 14, with 7 being neutral. In dairy processing, water pH has a direct effect on the performance of cleaning chemicals, the stability of dairy cultures, and equipment corrosion rates. A pH somewhere between 6.0 and 7.0 avoids corrosion of processing equipment while promoting effective chlorine sanitation. Most dairy operations target a broader acceptable range of 6.5 to 8.5 for general processing water.
The quickest field method is pH paper – strips impregnated with indicator dyes that change color in response to hydrogen ion concentration. A strip is dipped into the water sample and the resulting color is compared against a reference chart to read the pH value. While digital pH meters offer greater precision, pH paper remains practical for rapid, routine checks at multiple points across a dairy facility. It requires no calibration, no power source, and gives a result in seconds – making it well-suited for daily monitoring.
How pH affects chlorine effectiveness
An important interconnection exists between pH and chlorine efficacy. Free chlorine in water exists primarily as hypochlorous acid (HOCl) at lower pH, which is the germicidally active form. As pH rises above 7.5, more chlorine shifts to the hypochlorite ion form, which has far weaker antimicrobial power. This means pH monitoring is not just about corrosion control – it directly determines how effective the water’s disinfection capacity actually is.
Detecting sulphite ions by iodate-iodide titration
Sulphite ions (SOโยฒโป) in processing water are a sign of industrial contamination or improper water treatment. In dairy operations, sulphites can interfere with fermentation processes, affect starter cultures, and compromise the quality of cultured dairy products such as yogurt and cheese. They are reducing agents, meaning they can interact with oxidizing compounds in water treatment systems and disrupt the intended chemistry.
The test for sulphite ions involves titration with an iodate-iodide solution. When iodate and iodide are present together in an acidic medium, they generate iodine (Iโ). Sulphites in the water sample react with and consume this iodine. The titration continues until all sulphites have been oxidized, at which point excess iodine produces a visible color change – often detected with a starch indicator, which turns blue-black in the presence of free iodine. This end point marks the completion of the reaction, and the volume of iodate-iodide solution used is proportional to the sulphite concentration in the sample. The method is sensitive enough to detect low-level contamination that might otherwise go unnoticed.
Identifying phosphate ions by colorimetric methods
Phosphate ions in dairy plant water can originate from detergent residues (many cleaning agents are phosphate-based), agricultural runoff entering the water supply, or industrial discharge. Elevated phosphate levels can promote microbial growth, interfere with water treatment chemistry, and indicate inadequate rinsing of equipment after cleaning-in-place (CIP) procedures.
Phosphate testing in water relies on colorimetric methods. The most common approach involves adding a molybdate reagent to the water sample. Phosphate ions react with molybdate in an acidic solution to form a molybdophosphoric acid complex, which is then reduced to produce an intense blue color (molybdenum blue). The depth of the blue color is directly proportional to the phosphate concentration – the darker the color, the higher the phosphate level. The result can be read visually by comparing against color standards, or measured more precisely using a spectrophotometer. The FSSAI Manual for Analysis of Water specifies photometric measurement at specific wavelengths using calibration curves for accurate quantification.
This test is particularly relevant after cleaning cycles, as phosphate residues from detergents in rinse water suggest that equipment has not been adequately flushed – a food safety concern in any dairy environment.
Measuring residual chlorine: Tolidine and Chlorotex methods
Chlorine is the backbone of water disinfection in food-grade facilities. It is added to processing water to destroy bacteria, yeasts, molds, and spores. However, not all added chlorine remains active – some reacts with organic matter and is neutralized. The chlorine that remains active and available to continue sanitizing is called residual chlorine. Residual chlorine is the fraction that remains available in solution after the disinfection step is complete, when the initial added chlorine has been reduced by reaction, bound to organic matter, or evaporated.
In dairy processing, this balance is critical. Too little residual chlorine allows bacterial regrowth in pipelines and tanks; too much can interfere with starter cultures and fermentation, and impart off-flavors to finished products. Residual chlorine levels in water in direct food contact should not exceed the maximum residual disinfectant limit under the Safe Drinking Water Act.
The Tolidine (OT) method
The traditional method uses ortho-tolidine (OT) reagent, a colorimetric test in which the reagent is added directly to the water sample. Free chlorine oxidizes the colorless tolidine to produce a yellow color. The intensity of the yellow is proportional to the chlorine concentration and is matched against a color chart or series of color standards to determine the ppm value. The o-tolidine colorimetric method (OTO) is one of the two primary wet-chemistry methods used for residual chlorine detection. While reliable and simple, one limitation of the OT method is that it measures total chlorine rather than free chlorine specifically – a distinction that matters in food processing environments.
The Chlorotex method
The Chlorotex method is a more modern colorimetric approach using reagent tablets or reagent drops. When introduced to the water sample, the reagent reacts specifically with free chlorine to produce a measurable, stable color change. Experts recommend monitoring free chlorine, not total chlorine, to ensure proper disinfection, making methods that distinguish the two particularly valuable. The Chlorotex approach is generally considered more stable and gives more consistent results under varying field conditions compared to the traditional tolidine method. It is well-suited for routine daily testing at dairy plants.
Testing frequency and sampling strategy
Knowing which tests to run is only half the equation – when and where to test matters equally. A sound water quality management program in a dairy plant typically follows a tiered schedule: daily tests for pH and residual chlorine (since these are the most dynamic parameters), weekly tests for hardness, and monthly tests for sulphites and phosphates. Frequency should increase if there are known issues with the local water supply, after heavy rainfall (which can affect surface water sources), or following any changes to water treatment processes.
Sampling points should cover the full water journey through the facility – incoming municipal or borewell supply, water storage tanks, and multiple points along the processing lines. Water for laboratory analysis should be sampled into a clean plastic container, after repeatedly rinsing with the water to be tested, at the site of discharge into the water tank or trough – not at the origin of the reserve tank. Collecting samples only from a single inlet gives an incomplete picture; contamination can enter at any stage downstream.
Even if a water supply appears clean and safe, regular testing is important because it establishes a record of water quality over time – essential for regulatory audits, HACCP documentation, and troubleshooting product quality issues.
Connecting water quality to product quality
Each of the five tests described – hardness, pH, sulphite ions, phosphate ions, and residual chlorine – addresses a distinct risk in dairy processing. Hardness affects equipment efficiency and cleaning outcomes. pH governs cleaning chemical performance and chlorine efficacy. Sulphites signal industrial contamination that can disrupt fermentation. Phosphates reveal detergent carryover from cleaning. And residual chlorine confirms that disinfection is functioning without being excessive. Together, these parameters create a comprehensive chemical profile of water fitness for dairy use.
Routine testing is not a bureaucratic exercise – it is an early warning system. When water quality shifts, product quality often follows. Establishing a baseline through consistent testing allows dairy operators to detect changes before they reach the processing line, protecting both product integrity and consumer safety.
What do you think? Given that water quality can vary significantly by season or local source, how should dairy plants adapt their testing schedules to account for these fluctuations? And which of the five tests – hardness, pH, sulphites, phosphates, or residual chlorine – do you consider the most critical checkpoint for a dairy operation, and why?
References
- https://agscientific.com/blog/water-and-dairy-quality-testing.html
- https://fssai.gov.in/upload/uploadfiles/files/Manual_Water_Analysis_09_01_2017(1).pdf
- https://biocyclopedia.com/index/enivronmental_science_engineering_laboratory_methodology/determination_of_hardness_of_water_by_edta_titrimetric_method.php
- https://www.titrations.info/EDTA-titration-water-hardness
- https://www.cefns.nau.edu/~teb/ambl/sop/SOP_AMBL_104A_Hardness.pdf
- https://www.watertechonline.com/process-water/article/16210418/chlorine-testing-critical-in-food-processing-applications
- https://www.ams.usda.gov/sites/default/files/media/5026.pdf
- https://www.ams.usda.gov/rules-regulations/organic/handbook/5026
- https://pmc.ncbi.nlm.nih.gov/articles/PMC11356599/
- https://dairy-cattle.extension.org/evaluation-of-water-quality-and-nutrition-for-dairy-cattle/
Leave a Reply