Every litre of milk, block of cheese, or cup of yogurt that reaches a consumer has passed through equipment that must be rigorously cleaned and sanitized – often multiple times a day. In a dairy plant, the risk of contamination is ever-present: milk is rich in proteins, fats, sugars, and minerals that not only soil surfaces but also create ideal conditions for bacteria to grow. According to Penn State Extension, sanitation practices are the very foundation of dairy food processing, and a dairy processor must have a solid understanding of the key concepts in cleaning and sanitizing to produce safe, high-quality products. Cleaning and sanitization are not simply housekeeping tasks – they are critical control measures that protect consumers, preserve product quality, and ensure regulatory compliance.
Table of Contents
- Cleaning vs. sanitization: two distinct steps
- The four steps of an effective cleaning protocol
- Pre-rinse
- Wash
- Post-rinse
- Sanitization
- Methods of cleaning: CIP, COP, and manual
- Clean-in-place (CIP)
- Clean-out-of-place (COP)
- Manual cleaning
- Factors that affect cleaning effectiveness
- Temperature
- Chemical concentration and type
- Mechanical action
- Time and contact duration
- Water quality
- Why inadequate cleaning and sanitization is costly
- Monitoring and verification
Cleaning vs. sanitization: two distinct steps
These two terms are often used interchangeably, but they refer to different actions that must happen in a specific order. Cleaning is the physical removal of visible dirt, milk residues, and other unwanted matter from surfaces and equipment. Sanitization follows cleaning and is aimed at reducing the number of harmful microorganisms on those surfaces to safe levels. A critical principle in all dairy hygiene programs is that only a clean surface can be sanitized – applying a sanitizer to a soiled surface is largely ineffective because residues shield bacteria from chemical action.
Milk contains five main types of soil: carbohydrates (primarily lactose), proteins (casein and whey), fats, minerals, and microorganisms. Sugars typically dissolve in water and can be removed with warm water, while proteins may require chlorinated alkaline cleaners at high pH to be removed from surfaces. Fats need to be saponified – broken down into water-soluble compounds – while mineral deposits (milkstone) require acid-based cleaners. Because no single chemical addresses all these soil types, dairy cleaning programs generally use a sequence of alkaline and acid-based cleaning agents.
The four steps of an effective cleaning protocol
All good cleaning protocols involve at least four steps: pre-rinse, wash, post-rinse, and sanitizing. Removing any of these steps increases costs and results in inadequate cleaning.
Pre-rinse
The first step is a warm water rinse to remove loose soil and the bulk of milk residues before chemical cleaning begins. The pre-rinse phase is arguably the most important phase during the entire process, as it should remove 90-95% of milk soils. This step also prevents organic matter from being “cooked on” during the subsequent hot wash stages.
Wash
The wash step applies detergent solutions – alkaline, acid, or both – to break down and lift residual soils from surfaces. The four washing factors that determine effectiveness are time, mechanical action or force, chemical concentration, and temperature. The balance of these four factors must be properly calibrated for each piece of equipment and type of residue.
Post-rinse
After washing, a thorough rinse removes loosened soil and detergent residues. The post-rinse must be sufficient to carry away loosened soil and detergent, leaving equipment in a thoroughly clean condition. It is advisable to acidify the post-rinse whenever possible, as this prevents accumulation of alkaline residues and leaves surfaces at a slightly acidic pH that improves the bactericidal action of sanitizers applied subsequently.
Sanitization
Sanitizers are applied to equipment after cleaning steps have been properly completed, and are designed to kill all bacteria remaining on equipment surfaces. Common sanitizers used in dairy plants include chlorine-based compounds (sodium hypochlorite), iodophors, peracetic acid (PAA), and quaternary ammonium compounds. Each has specific advantages: peracetic acid has become increasingly favored because it is effective against all microorganisms including bacterial spores, leaves minimal residues, and is more eco-friendly in the wastewater stream, though it must be used in well-ventilated areas due to its strong odor. Chlorine remains widely used but can corrode stainless steel if not properly controlled.
Iodine sanitizers used in dairy plants are usually in the form of iodophors – iodine combined with non-ionic wetting agents. When diluted to proper concentrations, they have a low pH of 2.6-5.0, which enhances their germicidal qualities, particularly at temperatures up to 120ยฐF. Heat sanitization using hot water or steam is also used in certain applications as a chemical-free alternative, though it requires careful temperature management.
Methods of cleaning: CIP, COP, and manual
Dairy plants use three main cleaning methods, and the right choice depends on the type of equipment, its design, and production schedules.
Clean-in-place (CIP)
Cleaning-in-place (CIP) systems have been developed to achieve good cleaning and sanitation results, as earlier manual methods were not only laborious but often ineffective, and products were frequently reinfected from imperfectly cleaned equipment. CIP is now present in practically every modern milk processing plant. Cleaning-in-place refers specifically to the cleaning and sanitizing of dairy processing equipment and piping in its assembled condition, by recirculation of the necessary rinse, detergent, and sanitizing solutions under appropriate conditions of time, temperature, detergency, and physical action.
CIP is the method of choice for large-scale equipment – storage tanks, pasteurizers, pipelines, and heat exchangers. CIP systems pump cleaning, rinsing, and sanitizing solutions through the same piping path as the product to eliminate soil from all internal surfaces, minimizing the chance of human error and reducing chemical exposure for employees. In dairy facilities, CIP systems typically run every 24-48 hours depending on the production schedule.
Clean-out-of-place (COP)
COP cleaning is used for parts that are not designed for CIP cleaning and that can be disassembled and removed from process equipment. The COP tank recirculates hot wash solutions through jets over and through the components, providing the turbulence necessary for cleaning. This method is commonly used for valves, fittings, gaskets, and smaller removable components. A key advantage of COP is that it allows thorough visual inspection of hard-to-reach areas after cleaning.
Manual cleaning
Manual cleaning is typically performed with warm cleaning detergent and a dedicated, color-coded brush to clean parts in processing – such as personnel access covers and gaskets that cannot be easily removed for COP cleaning. While it is the most labor-intensive option and generally less consistent than automated methods, manual cleaning remains important for specific surfaces and tight spaces inaccessible to automated systems. Particular attention must be given to cleaning underneath gaskets, O-rings, and other small orifices where residue and bacteria tend to accumulate.
Factors that affect cleaning effectiveness
No single parameter determines whether a cleaning program succeeds – it is the combination of multiple interacting factors. Several factors impact cleaning: time, temperature, chemical concentration, mechanical effect, water quality, the type of soil being removed, the type of surface, cleaning method, and human factors. Understanding these variables helps operators design and troubleshoot cleaning programs effectively.
Temperature
As a rule of thumb, alkaline cleaning should be done at the same temperature as the product has been exposed to, but at least 70ยฐC, while temperatures of 60-75ยฐC are recommended for acid detergents. However, if the temperature is too high, proteins can denature and bind more firmly to surfaces, making them harder to remove. Conversely, water that is too cold will not melt fats or activate cleaning chemicals effectively. For manual cleaning, water should be at least 120ยฐF (49ยฐC) to ensure that fat is melted and removed by the cleaning solution.
Chemical concentration and type
Increasing chemical concentration does not necessarily improve cleaning effect – too high a concentration may cause foaming or make protein fouling more compact and harder to remove, while also adding unnecessary cost and chemical load to wastewater. Alkaline detergents are primarily used to saponify fats and solubilize proteins, while acid detergents neutralize alkaline residues and dissolve mineral deposits (milkstone). Using an acid detergent without first removing fats and proteins with an alkaline detergent will result in fixing protein soil to the surface – a common and costly mistake.
Mechanical action
In CIP cleaning, mechanical action is provided by direct impingement of spray streams, cascading flow down vessel sidewalls, or turbulent flow through pipelines at a minimum flow rate of 5 feet per second (1.5 m/s). This turbulence is what dislodges attached biofilms and residues from surfaces that chemicals alone cannot always remove. In manual cleaning, the operator’s scrubbing action serves the same purpose.
Time and contact duration
Each step in the cleaning cycle requires sufficient contact time for the chemistry to work. Cleaning action must be long enough and at the proper temperature and detergent concentration to loosen and break up remaining soil so it can be removed by physical and chemical action. Rushing or shortening cleaning steps is one of the most common causes of residual contamination in dairy plants.
Water quality
Water hardness is a significant but often overlooked factor. Hard water – water with high concentrations of calcium and magnesium ions – can interfere with detergent performance and deposit milkstone on equipment surfaces. Water over 100 ppm hardness should be softened for use in cleaning systems, and water conditioning should be incorporated into any comprehensive cleaning program design.
Why inadequate cleaning and sanitization is costly
The primary purpose of cleaning dairy equipment after each use is to remove all residues. Residues provide harborage for bacterial growth that affects product quality and shelf life and has the potential to cause disease. When cleaning fails, the consequences extend well beyond the plant floor. Contaminated dairy products can trigger foodborne illness outbreaks, product recalls, and regulatory shutdowns. Bacterial contamination also shortens shelf life and creates economic losses for processors.
Milk and milk products are ideal media for the growth of microorganisms, including many pathogens. As a result, there is more legislation concerning milk – its production, handling, processing, packaging, storage, and distribution – than any other food product. Processors must comply with frameworks such as the Food Safety Modernization Act (FSMA), and must maintain documented Sanitation Standard Operating Procedures (SSOPs) that ensure every employee follows correct procedures consistently. Improper cleaning and sanitizing protocols have resulted in high costs, product spoilage, equipment damage, and hospitalization of personnel.
Monitoring and verification
A cleaning program is only as good as its verification system. As there are no techniques currently available for measuring cleanliness continuously in-line, plants must be opened after cleaning at predetermined critical control points to assess cleanliness. A quick verification method is to test for the presence of adenosine triphosphate (ATP) using an enzyme that emits light when in contact with ATP, indicating the presence of a living organism or substance produced by one. Microbiological swabbing and chemical tests for protein residues and sanitizer concentration provide additional layers of verification. All CIP records must be retained by the plant for a minimum of three months, and log records of manual cleaning operations are also recommended to support quality control and regulatory review.
What do you think? Given that temperature, time, chemical action, and mechanical force all interact in cleaning outcomes, which factor do you think is most commonly compromised in dairy plant operations – and what practical steps could help ensure it is consistently controlled? If you were designing a new dairy processing facility, how would equipment design choices influence the ease and effectiveness of your cleaning and sanitization program?
References
- https://extension.psu.edu/food-safety-and-quality/dairy-food-processing/safety-and-sanitation
- https://extension.psu.edu/key-concepts-of-cleaning-and-sanitizing
- https://www.bccdc.ca/resource-gallery/Documents/Educational%20Materials/EH/FPS/Food/DairyProcessingCleaning.pdf
- https://agrochemusa.com/maximize-performance-efficiency-of-cip-routines/
- https://extension.psu.edu/cleaning-small-scale-dairy-plants-cleaning-equipment
- https://health.maryland.gov/phpa/OEHFP/OFPCHS/Milk/Shared%20Documents/DPC029_Cleaning_Sanitizing_Fluid_Milk_Plants.pdf
- https://www.csidesigns.com/blog/articles/5-steps-in-a-common-food-dairy-beverage-clean-in-place-cycle
- https://www.ndvsu.org/images/StudyMaterials/LPT/cleaning_and_sanitation_of_milk_plant.pdf
- https://dairyprocessinghandbook.tetrapak.com/chapter/cleaning-dairy-equipment
- https://www.dairyfoods.com/articles/95600-dairy-equipment-cleaning-cip-vs-cop